# What Is a CCC for a Factory? | Factory Builder Malaysia

> What a CCC certifies for a factory, who issues it, the clearances behind it and why occupation waits for it.

URL: https://factorybuilder.my/guide/what-is-ccc-for-factory/
Last-Modified: 2026-11-10
Tags: ccc for factory malaysia, certificate of completion and compliance, principal submitting person, factory handover ccc

menu\_book Explainer // Factory construction

# What Is a CCC for a Factory and When Is It Issued?

What a CCC certifies for a factory, who issues it, the clearances behind it and why occupation waits for it.

Published 10 November 2026 · 5 min read

![Newly completed factory with an office frontage in Selangor](/images/featured/newly-completed-factory-with-office-frontage-in-se.webp)

## What Does a CCC Certify?

The **Certificate of Completion and Compliance (CCC)** says a building is finished and complies with its approved plans. For a new factory, it is the last formal step before you move in. It confirms that the structure, the fire safety provisions and the key services were built as approved, and that the relevant agencies have signed off their parts.

We’re Factory Builder Malaysia, the factory and warehouse building arm of QDB Ventures Sdn Bhd, a Cheras-based contractor that builds in Selangor. A CCC for a factory in Malaysia is something we plan around from day one.

If you are planning 

factory construction

[/ →](/)

 in Selangor, understand the CCC from the start. The way the building is designed and built decides how smoothly it is issued at the end.

![Fire hydrant and hose reel cabinet beside a completed factory wall](/images/content/red-fire-hydrant-and-hose-reel-cabinet-beside-comp.webp)

### The CCC Replaced the Old CF

Yes, the CCC replaced the old certificate, formally called the Certificate of Fitness for Occupation (CFO), which the local council used to issue. According to the Malaysian Bar, the change came with the Street, Drainage and Building (Amendment) Act 2007, which took effect on 12 April 2007.

The council no longer signs off your building. Qualified professionals do. That puts more responsibility on the people who design and supervise it, and it’s why your choice of professional matters.

## Who Issues the CCC?

The CCC is certified by the **principal submitting person (PSP)**, the qualified professional who submitted the building plans. This is usually an architect or a professional engineer. They supervise the works and certify completion and compliance at the end.

Here’s what the PSP handles on your behalf:

-   **Supervising the works** from start to finish
-   **Collecting stage certifications** from the contractor and other professionals. The Board of Engineers Malaysia says these come as 21 forms, Form G1 to G21
-   **Signing Form F**, which is the CCC itself. Only the PSP can sign it
-   **Depositing copies** of the certificate and the Form Gs with the local authority and the relevant professional board within 14 days, as By-law 25(3) of the Uniform Building By-Laws 1984 requires
-   **Issuing a partial CCC (Form F1)** if the project finishes in phases

This is why the PSP’s role matters so much. Under By-law 25(2), the PSP accepts full responsibility and certifies that the building is safe and fit for occupation. They’re signing their name to the fact that the building matches what was approved.

> **Late changes are the enemy of a smooth CCC**
> 
> A change made on site without updating the approved plans can hold up the CCC. Decide early, and record any change properly.
> 
> A 2026 guide from FactoryHub points out that deviating from approved plans without the council’s written permission is a separate offence under section 70(13) of the Street, Drainage and Building Act 1974. The fine can reach RM50,000, with up to three years’ jail.

## The Clearances Behind the CCC

Before the CCC can be issued, the agencies responsible for each part of the building must be satisfied. For a typical factory, these include:

| Agency | What they clear |
| --- | --- |
| TNB | Power supply connection and any substation |
| Air Selangor | Water supply connection |
| Indah Water | Sewerage connection |
| Telekom Malaysia | Telecommunication connection |
| Bomba | Fire safety: escape routes, hydrants, hose reels, sprinklers where required |
| Council departments | Roads, drainage, landscaping and other conditions |

Each clearance depends on the matching part of the building being designed and built correctly. Fire safety is a common sticking point, which is why we raise Bomba requirements during detailed engineering. Our guide on 

what Bomba, DOE and DOSH need from a new factory

[/guide/bomba-doe-dosh-factory-requirements/ →](/guide/bomba-doe-dosh-factory-requirements/)

 covers this.

One distinction trips up first-time owners. The CCC is not Bomba’s fire certificate (Perakuan Bomba). According to Industrial Malaysia, you apply for the fire certificate after the CCC is issued, and Bomba asks for a copy of the CCC. FactoryHub adds that the fire certificate must be renewed every year.

## Why Occupation Waits for the CCC

Occupation should wait for the CCC, even when the roof is on and a lease is ending. It’s tempting to move machinery in early. Without the certificate, you may face problems with:

-   **Utility connections**, which may not be fully energised or connected
-   **Insurance**, which may not cover an uncertified building
-   **Licences** for your business at the premises
-   **Financing**, if a bank needs the CCC before releasing funds

The law is firm too. Under section 70(27) of the Street, Drainage and Building Act 1974, occupying a building without a CCC can lead to a fine of up to RM250,000, up to 10 years’ jail, or both. The Malaysian Bar notes that this can reach owners, tenants and other occupiers.

If your timeline is tight, build the CCC into the programme from the start rather than hoping to squeeze it in at the end. A phased build can help. Ask your PSP about a partial CCC (Form F1), though the Board of Engineers Malaysia says the PSP needs the local authority’s permission to use that form. Our guide on 

how long it takes to build a factory

[/guide/how-long-to-build-a-factory/ →](/guide/how-long-to-build-a-factory/)

 explains how the stages fit together.

## How the CCC Fits the Approval Path

The CCC is the final step in a sequence that starts with planning permission and building plan approval. Our guide to 

factory building approvals in Selangor

[/guide/factory-building-approvals-selangor/ →](/guide/factory-building-approvals-selangor/)

 walks through that sequence in order.

When you appoint a contractor, ask these questions up front:

-   Who will be the principal submitting person?
-   Who is responsible for each agency clearance?
-   Who collects and files the stage certifications (Form G)?
-   Will the project need a partial CCC for phased handover?

Our quotations state these responsibilities in writing, so you know exactly who is handling what on the way to the CCC. Send us your land details and we’ll show you how it would work for your factory.

helpQuick answers

## Frequently Asked Questions

### Who issues the CCC?

expand\_more

The CCC is certified by the principal submitting person, the qualified professional (usually an architect or professional engineer) who submitted the building plans. They certify that the building was completed and complies with the approved plans and requirements.

### Can I occupy the factory before the CCC?

expand\_more

Occupation should wait for the CCC. Moving in early can affect insurance, utility connections and your ability to get licences for the premises, and it can breach local rules.

### Which agencies must clear first?

expand\_more

Typically TNB for power, Air Selangor for water, Indah Water for sewerage and Bomba for fire safety, plus the council's own departments. Their clearances feed into the CCC.

### What causes CCC delays?

expand\_more

Usually work that does not match the approved plans, missing agency clearances, or late changes that were not approved. Getting the details right during design and construction is the best protection.

menu\_bookKeep reading

## Related Guides

### Factory Building Approvals in Selangor: From Planning Permission to CCC

The approval path for a new factory in Selangor: planning permission, building plan approval, OSC submissions and the CCC at completion.

[Factory Building Approvals in Selangor: From Planning Permission to CCC →](/guide/factory-building-approvals-selangor/)

### After Handover: Defects Liability, As-Built Drawings and Future Extensions

After factory handover: defects liability, who fixes roof leaks or floor cracks, the documents you get and planning to extend.

[After Handover: Defects Liability, As-Built Drawings and Future Extensions →](/guide/after-factory-handover/)

### What Bomba, DOE and DOSH Need From a New Factory Building

Fire, environmental and workplace safety needs a new factory must plan for, and why to raise them in detailed engineering.

[What Bomba, DOE and DOSH Need From a New Factory Building →](/guide/bomba-doe-dosh-factory-requirements/)

### Build, Buy or Rent a Factory: How to Decide

Renting, buying ready-built or building on your own land: fit to your production line, control, timing and a checklist.

[Build, Buy or Rent a Factory: How to Decide →](/guide/build-buy-or-rent-factory/)

From guide to project

## Talk to our engineers about your project

Send your site, intended use and budget, even if some details are missing. We review the brief and set out the construction plan, budget and next steps.

Contact us

[/contact/ →](/contact/)

 

Request a Quotation

[/contact/ →](/contact/)
